Showing results: 31 - 45 of 143 items found.
-
196762-01 -
NI
The TB-2636 provides the necessary routing to configure the PXI-2529 PXI Matrix Switch Module as a 2-wire 4×32 matrix. You can directly connect the TB-2636 to the front panel I/O connectors of the PXI-2529. The TB-2636 includes screw terminals that provide access to the rows and columns of the matrix.
-
781687-01 -
NI
The TB-2630B provides the necessary routing to configure the PXI-2630B PXI Multiplexer Switch Module as a single, dual, or quad 1-, 2, or 4-wire multiplexer. You can directly connect the TB-2630B to the front panel I/O connectors of the PXI-2630B. The NI TB-2630B features ribbon cable headers to connect signals to the PXI Multiplexer Switch Module as well as screw terminals for trigger input and trigger output signals.
-
781131-04 -
NI
Screw Terminal, 8x32, Dual 1-Wire PXI Module Matrix Terminal Block - The TB-2651 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire dual 8x32 matrix. You can directly connect the TB-2651 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
781131-02 -
NI
Screw Terminal, 4x64, Dual 1-Wire PXI Module Matrix Terminal Block - The TB-2649 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire dual 4x64 matrix. You can directly connect the TB-2649 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
781131-03 -
NI
The TB-2650 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire 8x64 matrix. You can directly connect the TB-2650 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
781131-01 -
NI
Screw Terminal, 4x128, 1-Wire PXI Module Matrix Terminal Block - The TB-2648 provides the necessary routing to configure the PXI-2531 or PXIe-2531 PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2648 to the front panel I/O connectors of the PXI-2531 or PXIe-2531.
-
781688-01 -
NI
The TB-2631B provides a PXI front-mounting terminal block to configure the PXI-2530B PXI Multiplexer Switch Module. It provides direct signal wire connections to the screw terminals inside the terminal block.
-
782385-13 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-11 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-12 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-10 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-14 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-01 -
NI
Screw Terminal, Ribbon, 4x128, 1-Wire PXI Module Matrix Terminal Block - The TB-2640B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2640B to the front panel I/O connectors … of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2640B also provides optional isolation resistors to protect the reed relays from capacitive loads.This 782385-01 card does NOT have 100 Ohm protection.
-
782385-02 -
NI
The TB-2640B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 1-wire 4x128 matrix. You can directly connect the TB-2640B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2640B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
40-201-004 -
Pickering Interfaces Ltd.
This high bandwidth differential fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.